Dongguan touch switch power supply Common Troubleshooting


  Dongguan touch switch power supply Common Troubleshooting
  I. Symptom : Power supply indicator does not light .
  Check the contents : The power is connected, the knife is closed , if it is whether there is phase three-phase power .
  Remedy: connect the power , closed knife
  Second, the failure phenomenon: the power indicator is normal, the fan normal , light does not work .
  Check the contents : Start switch is in the start position
  Remedy: If the start switch is in the start position , the machine does not work, then struck again start switch to the start position
  Third, the failure phenomenon: the normal working indicator , current and voltage adjustment does not move .
  Check the contents : Check the regulator steady flow limiting and limited pressure knob is set to minimum position
  Remedy: limiting the voltage regulator , steady flow pressure limiting knob screw plating process requirements to a proper position
  Fourth, the failure phenomenon: work which, suddenly no current output, working lights normally.
  Check the contents : Check the output from the power supply to the plating tank connection is disconnected
  Remedy: Replace or reconnect cables
  V. Symptom: work which, suddenly there is no current output , protection indicator flashes.
  Check the contents : 1, check the working environment temperature is too high , the fan is working properly
  Remedy : Exclude fan failure , improved ventilation
  Check the contents : 2, determine whether the instantaneous overcurrent
  Remedy: Press the boot reboot , power can work
  Check the contents : 3, the input voltage is normal , with or without overvoltage, undervoltage , phase three-phase input without
  Remedy : Exclude distribution lines, power failures , according to reboot the boot process
  Check the contents : 4, check the power rectifier for shorts
  Remedy: Replace rectifier
  Check the contents : 5, check for damage power devices , the input rectifier module for damage
  Remedy: Replace the same type of power device and driver circuit checked for damage , there is then replaced, the replacement input plating rectifier modules.
Index / Company / Prodcuts / Workshop / Business / News / Technology / Job / Feedback / Contact
Dongguan OPPHO Electronics Co., Ltd all rights reserved@ Copyright
The phone:0769-83393855/83397855 Fax:86-769-8339-8055 Access amount: Email Login
*All of photos, text and other information contained in the website are reserved by Dongguan OPPHO Electronics Co., Ltd
and it is not allowed make reproduction without consent* [Background management]